ORA-609 : OPIODR ABORTING PROCESS UNKNOWN OSPID

ORA-609 : OPIODR ABORTING PROCESS UNKNOWN OSPID
ORA-609 : opiodr aborting process unknown ospid

WARNING: inbound connection timed out (ORA-3136)


Cause:

The ORA-609 error is thrown when a client connection of any kind failed to complete or aborted the connection
process before the server process was completely spawned.
Beginning with 10gR2, a default value for inbound connect timeout has been set at 60 seconds.

This is also triggered, when a DB session is killed/aborted manually from the OS prompt.

Solution:

Increase the values for INBOUND_CONNECT_TIMEOUT at both listener and server side sqlnet.ora file as a preventive measure.If the problem  is due to connection timeouts,an increase in the following parameters should eliminate or reduce the occurrence of the ORA-609s.

Sqlnet.ora: SQLNET.INBOUND_CONNECT_TIMEOUT=180
Listener.ora: INBOUND_CONNECT_TIMEOUT_listener_name=120

No comments:

ORA-00059: Maximum Number Of DB_FILES Exceeded in 19C database

When I am adding datafile to my 19C database facing the below error. SQL> alter tablespace DATA  add datafile '/u01/data/data15.dbf...